Table 302: PKT-BUS Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

2049 (e) 1–3 Maintenance/Test<br />

Circuit Pack<br />

Query test (#572)<br />

2305 (f) 1–2<br />

4<br />

Associated Test Alarm<br />

Level<br />

Maintenance/Test<br />

Circuit Pack<br />

Query test (#572)<br />

On/Off<br />

Board 1<br />

PKT-BUS (Packet Bus)<br />

MIN ON test pkt port-network P l r 2<br />

test pkt port-network P l<br />

3329 (g) 1–7 WRN ON test pkt port-network P l<br />

3585 (h) Any MIN ON test pkt port-network P l<br />

3841 (i) Any MIN OFF<br />

1. ON-BOARD indicates a problem with the packet bus itself.<br />

Recommended Action<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description and follow its procedures.<br />

b. Error Type 1: Within the last minute, packet circuit packs have reported errors that indicate<br />

a possible packet bus failure. The Aux Data value is 1 or 2, indicating that only one or more<br />

than one Packet circuit pack (respectively) have reported a possible packet bus failure.<br />

c. Error Type 513: The Maintenance/Test packet bus port (M/T-PKT) for this port network has<br />

determined that there are more packet bus faults than the port can correct. The Aux Data<br />

value indicates the number of faulty leads.<br />

d. Error Type 1793: Packet circuit packs have detected possible packet bus failures via inline<br />

error or via background test failure. Examine the Error and Alarm logs for more specific<br />

PKT-BUS errors.<br />

e. Error Type 2049: S8700-series Fiber-PNC: The Maintenance/Test packet bus port (M/T-PKT)<br />

has detected a Packet Bus fault and has taken corrective action by swapping to spare<br />

leads. This error appears only in high/critical-reliability systems (duplicated PNC). The Aux<br />

Data value indicates the number of faulty leads. If this is the only active error against the<br />

packet bus, the packet bus is still in service. Due to the disruptive nature of the packet bus<br />

Fault Isolation and Correction procedures, repairs should be deferred until a time when the<br />

least interruption in service would result. This should be determined by consultation with the<br />

customer. However, do not delay repairs for too long, since the switch cannot recover from<br />

another packet bus failure until the current one is resolved. Isolating and repairing<br />

packet-bus faults in Maintenance Procedures (03-300432) contains a sub-section, A<br />

Special Precaution Concerning the TN771D that describes how to ensure that the TN771D<br />

is providing correct information. A new TN771D may need to be taken to the customer site.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1083