Communication Manager Maintenance Object Repair Procedures<br />

● In a CSS configuration, replace the Switch Node Interface circuit pack connected to<br />

the active Expansion Interface circuit pack in the master port network. Use list<br />

fiber-link to determine the Switch Node Interface circuit pack that is connected to<br />

the active Expansion Interface circuit pack in the master port network.<br />

● If the problem persists and any slip errors remain, follow the procedures described in<br />

the troubleshooting section above.<br />

It may take up to one hour to clear the alarm after the problem has been resolved.<br />

i. Noise on the DS1 line can cause transient alarms on synchronization. Therefore, when a<br />

sync problem occurs on Error Types 1, 257, or 513, a WRN alarm is first raised for 15 to 20<br />

minutes before the alarm is upgraded to a MINOR or MAJOR alarm.<br />

Table 343: Synchronization Error Log Entries<br />

Error Type Aux<br />

Data<br />

0 1<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 Any Any Any test synchronization<br />

1 (a) (g) Any WRN<br />

MIN (j) 2<br />

OFF<br />

18 (b) 0 disable sync WRN OFF enable sync<br />

257 (c)(g) Any WRN<br />

MIN (j) 2<br />

OFF<br />

513 (d)(g) Any WRN<br />

2<br />

MAJ (j)<br />

OFF<br />

769 (e) MAJ<br />

WRN 3<br />

OFF<br />

1793 4<br />

0-50 MAJ<br />

WRN<br />

OFF enable sync<br />

2049 (f) 4<br />

0 WRN OFF<br />

2305 (f) 4<br />

0 WRN OFF<br />

1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate<br />

test description and follow the recommended procedures.<br />

2. This Error Type initially raises a Warning alarm. If this Error Type persists and alarms are not<br />

downgraded on this MO due to the value of set options, then, after a period of time, a Minor or Major<br />

alarm is raised.<br />

3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in set<br />

options.<br />

4. It can take up to one hour for these SYNC alarms to clear.<br />

1280 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s