Communication Manager Maintenance Object Repair Procedures<br />

This test runs on SNI-BD (SNI Circuit Pack) and SNI-PEER (SNI Peer Link).<br />

Table 538: Packet Neighbor Link Test (#767) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this test could not be sent.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2301 ABORT The software timer could not be set before sending the downlink message<br />

necessary to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2302 ABORT Software received incorrect message data from the SNI circuit pack.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2303 ABORT The SNI circuit pack responded that the software test requested is invalid.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2304 ABORT SNI firmware is not able to run the test. For this particular test, the SNI<br />

circuit pack must be able to communicate with its neighbor.<br />

1. Verify that the SNI can communicate with its neighbor by checking the<br />

yellow LED of the SNI to make sure the SNI is in frame, or by running<br />

test board for the SNI and checking test 989 for fiber out-of-frame.<br />

If the results of Test 989 indicate that the fiber is out-of-frame, follow<br />

the recommendation associated with the test failure. If a DS1<br />

converter complex exists on the fiber link, enter display errors<br />

and follow the repair procedures for any DS1C-BD and DS1-FAC<br />

entries.<br />

2. Retry the command at 1-minute intervals up to 3 times.<br />