Table 183: DIOD-DS1 Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

2305 (l) 50944<br />

2562 (m) 16665<br />

2817 (n) 52992<br />

Associated Test Alarm<br />

Level<br />

3840 (o) Port Audit and<br />

Update (#36)<br />

On/Off<br />

Board<br />

DIOD-DS1 (DS1 DIOD Trunk)<br />

Recommended Action<br />

1. This alarm is raised when the Base Tone Generator field is 4 (Italy) on the System-Parameter<br />

Country screen. This alarm is MINOR unless 75% or more trunks in this trunk group are out of service, then<br />

the alarm is upgraded to a MAJOR alarm.<br />

2. Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its recommended procedures.<br />

b. Error Type 1<br />

Aux Data 57408: No tip ground is detected on an outgoing call.<br />

Aux Data 57476: Rotary Dial before Wink.<br />

Aux Data 57477: Rotary Dial pulse too early.<br />

Aux Data 57485: Wink too short for a valid signal.<br />

Aux Data 57487: PBX could not get “loop close” signal.<br />

The DS1 Interface circuit pack detected a hardware fault. These errors will cause the DS1<br />

CO Trunk Dial Tone test (#314) to run and are only considered a problem if the Dial Tone<br />

test fails (in which case Error Type 1025 will also show up). In this case, the trunk may be<br />

put in the ready-for-service state (shown as “disconnected” by the status command), which<br />

allows only incoming calls. Run the DS1 CO Trunk Dial Tone Seizure Test (#314) and follow<br />

the procedures.<br />

c. Error Type 15: software audit error that does not indicate any hardware malfunction. Run<br />

short test sequence, and investigate any errors.<br />

d. Error Type 18: the trunk has been busied out and is in the out-of-service state. No calls can<br />

be made on this trunk except Facility Access Test Calls. For details, see Facility test calls in<br />

Maintenance Procedures (03-300432).<br />

e. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the error, reinsert or replace the circuit pack.<br />

f. Error Type 257: The DS1 Interface circuit pack detects a hardware fault. Aux Data 57392<br />

indicates no external release on PBX disconnect.<br />

Communication Manager Release 5.0 Issue 4 January 2008 707