Communication Manager Maintenance Object Repair Procedures<br />

TIE-TRK (Analog Tie Trunk)<br />

MO Name In Log Alarm Level Initial Command to Run 1<br />

TIE-TRK MAJ 2<br />

MIN<br />

1. If ATMS testing is enabled, check the error log for ATMS errors 3840 and 3841. If the error log<br />

indicates that measurements exceeded acceptable thresholds, and no other trouble is found with<br />

test trunk, run the ATMS test call with test analog-testcall port location full.<br />

Note:<br />

Note: Many trunk problems are caused by incorrect settings of parameters on the trunk<br />

group administration screen. Settings must be compatible with the local<br />

environment and with parameter settings on the far end. Refer to Administrator<br />

Guide for <strong>Avaya</strong> Communication Manager, 03-300509. Refer to your <strong>Avaya</strong><br />

representative for the correct settings for administrable timers and other<br />

parameters on a country-by-country basis.<br />

The following circuit packs, including every suffix such as TN760D, support analog tie trunks:<br />

Each tie trunk circuit pack occupies a port circuit pack slot and contains 4 port circuits. Each port<br />

circuit supports 1 analog tie trunk used to connect the switch to another PBX across 1- or 2-way<br />

dedicated circuits (see preceding list).<br />

A tie trunk port can also be administered as an access endpoint which is a non-signaling<br />

channel with a voice-grade data bandwidth. Tie trunk maintenance employs up to 6 tests,<br />

depending on the hardware involved, to monitor the operating condition of the trunk and its<br />

1338 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

Full Name of MO<br />

2. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

and that at least 75 percent of the trunks in this trunk group are alarmed.<br />

This alarm does not apply to TN497.<br />

test port location l Analog Tie Trunk<br />

WRN test port location<br />

Table 358: Analog Tie Trunk Circuit Packs<br />

Code Trunk Type Signaling Leads<br />

TN760 4-wire E&M<br />

TN437 4-wire E&M<br />

TN439 2-wire A&B (2-way circuits only)<br />

TN458 4-wire E&M<br />

TN497 2-wire A&B<br />

TN2140 4-wire E&M