Demand test descriptions and error codes<br />

DS1C-BD (DS1 Converter Circuit Pack)<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Tests 788 and 789 are executed by the TN574 DS1 Converter circuit pack only.<br />

Note: Test<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

Note:<br />

#984 is not an actual demand maintenance test. This test number reports<br />

the results from clear firmware-counters. Refer to the table for Failure<br />

Audit Test (#949) to interpret ABORT codes for Test #984.<br />

D/ND 1<br />

Failure Audit Test (#949) X X ND<br />

DS1 Facilities Connectivity Test (#790) X D<br />

Far-End DS1 Converter Circuit Pack Loopback Test<br />

(#788)<br />

X D<br />

Far-End Lightwave Transceiver Loopback Test (#789) X D<br />

DS1C Board Options Audit (#795) X X ND<br />

The following test is executed as part of the reset board command<br />

Reset Board Test (#787) D<br />

Communication Manager Release 5.0 Issue 4 January 2008 769