ANL-LINE (8-Port Analog Line)<br />

MO Name in Log Alarm<br />

Level<br />

Error log entries and tests apply to ANL-LINE and ANL-NE-L.<br />

The 8-port Analog Line circuit packs,<br />

ANL-LINE (8-Port Analog Line)<br />

Initial Command To Run Full Name of MO<br />

ANL-LINE MIN test port location l 8-Port Analog Line<br />

WRN test port location<br />

ANL-NE-L MIN test port location l 8-Port Neon Analog Line<br />

WRN test port location<br />

TN411 TN443 TN467<br />

TN712 TN742 TN769<br />

provide eight ports for single-line, on or off-premises analog endpoints such as analog voice<br />

terminals, queue warning level lamps, recorded announcements, dictation machines,<br />

PAGEPAC paging equipment, external alerting devices, modems, fax machines, and AUDIX<br />

voice ports. Only the TN769 supports a neon message waiting lamp.<br />

Note:<br />

Note: PAGEPAC is a registered trademark of Harris Corporation, Dragon Division.<br />

Test #48 may cause some terminal equipment to ring briefly during daily maintenance, which<br />

may disturb the customer or the terminal equipment. Test #47 may cause a false alarm when<br />

the port is connected to certain off-premises equipment, non-voice terminal equipment, or loop<br />

equipment. In either case, the tests can be disabled by entering n in the Tests field on the<br />

change station extension screen. Be aware that this will disable Tests 6, 35, 47, and 48.<br />

No maintenance of the terminal connected to the 8-Port Analog Line circuit pack or 8-Port Neon<br />

Analog Line circuit pack is performed, except to determine whether or not the terminal is<br />

connected. Failures of the common ringing application circuitry and the neon message waiting<br />

lamp power (ANL-NE-L only) are reported as errors 1281and 1793 against XXX-BD (Common<br />

Port Circuit Pack) in Common Port Circuit Pack Maintenance Error Log Entries.<br />