Communication Manager Maintenance Object Repair Procedures<br />

● RANL-STA (Remote Analog Line (Station) Port)<br />

Table 396: ONS Ringer Application Test (#48) 1 of 2<br />

Error<br />

Code<br />

1000<br />

1004<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

ABORT System resources required to run this test are not available or the port<br />

was seized with a valid call during the test.<br />

1. Enter display port location to determine the station<br />

extension.<br />

2. Enter status station extension to determine the service state<br />

of the port. If the port is in use, wait until the port is idle.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT This test is not applicable for this type of port. This error can be ignored.<br />

1008 ABORT Could not allocate a ringing circuit. Either every ringing circuit is in use,<br />

or the ringing generator is defective or incorrectly wired.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2. If the test continues to abort, look for RING-GEN errors in the Error<br />

Log. If an ABORT 1008 occurs for this test on other circuit packs as<br />

well, then the ringing generator may be defective or incorrectly wired<br />

See RING-GEN (Analog Ring Generator).<br />

3. If ABORT 1008 does not occur on other ports, then all four ring<br />

phases are in use.<br />

1018 ABORT The test has been disabled by administration. Determine why the Test<br />

field on the change station screen has been set to n for this station. It<br />

may be due to the brief ringing disturbance that this test may cause.<br />

1. To enable the test for the particular analog station, enter<br />

change station extension and set the Test field to y.<br />

2000 ABORT Response to the test was not received within the time allowed.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />