Communication Manager Maintenance Object Repair Procedures<br />

Figure 150: ATM Board Framer Looparound Test (#1260) (non-EAA, Packet Path)<br />

Table 594: ATM Board Framer Looparound Test (#1260) 1 of 5<br />

Error<br />

Code<br />

Packet<br />

interface<br />

Test<br />

Result<br />

Packet bus<br />

(PPN)<br />

ATM<br />

circuit<br />

pack<br />

PNC mode<br />

ATM<br />

switch<br />

ATM<br />

framer<br />

looped<br />

Description / Recommendation<br />

ATM<br />

circuit<br />

pack<br />

PNC mode<br />

ATM<br />

circuit<br />

pack<br />

ATM<br />

expansion<br />

archangel<br />

PNC mode<br />

TDM bus<br />

(EPN X)<br />

Packet bus<br />

(EPN X)<br />

Tone clock<br />

Tone detector<br />

iodfpak AWF 040699<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS errors. A system is considered under heavy traffic when<br />

the Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed<br />

65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the test. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) errors.<br />

3. Resolve any TONE-PT (Tone Generator) errors.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />