Communication Manager Maintenance Object Repair Procedures<br />

Table 537: Switch Node Interface Reset Test (#761) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2306 ABORT The SNI circuit pack is not responding to test requests sent by software.<br />

1. Run test led switch-node for the switch node where the SNI<br />

resides to verify whether the LEDs on the board light.<br />

2. If the LEDs on the other boards in the carrier light, but the LEDs on<br />

this board do not light, run test 760 using test board location<br />

l for the active SNC in this carrier. Wait 5 minutes and then try step 1<br />

one more time. If the LEDs on this board still do not light, replace this<br />

board. Replacing an SNI may be service interrupting. See SNI-BD<br />

(SNI Circuit Pack) for the procedure for replacing an SNI.<br />

3. If none of the LEDs light for the boards in the same carrier as this<br />

board, fix any problems associated with the connectivity of this carrier<br />

to the server.<br />

a. Check list fiber-link to see the fiber connections to this<br />

carrier.<br />

b. Check the LEDs on every SNI and EI, and fix any fiber problems.<br />

c. Enter display errors, and follow the repair procedures for any<br />

EXP-INTF error entries associated with the controlling IPSI<br />

connected PN.<br />

d. Also, follow the repair procedures if there are errors for any of the<br />

following:<br />

● SYNC (Port Network Synchronization)<br />

● SNI-BD (SNI Circuit Pack)<br />

● SNC-BD (Switch Node Clock Circuit Pack)<br />

● FIBER-LK (Fiber Link)<br />

● SNI-PEER (SNI Peer Link)<br />

4. Follow the Switch Node Interface Manual Loopback Procedure to<br />

determine whether the circuit pack or the fiber connection is faulty.<br />

2316 ABORT The reset of the SNI circuit pack was attempted via the connected DS1C<br />

circuit pack. This ABORT code indicates that the fiber is not<br />

administered, but in this particular case it also indicates a software<br />

problem.<br />

1. Retry the command at 1-minute intervals up to 1 time.<br />