PRI-CDR (Call Detail Recording Link)<br />

e. Error Type 1025: the CDR output device is in an off-line state, (for example, due to paper<br />

jam or paper out for a printer device). The CDR link is torn down.<br />

1. Check the CDR output device and act promptly to put it back to on-line state.<br />

2. Enter test cdr-link primary | secondary command to set up the CDR link.<br />

f. Error Type 1281: overflow of CDR records generated in the switch due to the heavy trunk<br />

traffic and low speed CDR output device. If both primary and secondary links are ON, the<br />

secondary link is torn down temporarily for two minutes to speed up the output process to<br />

the primary link. No action is necessary for this Error Type.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND<br />

Link Tear Down Test (#213) X Destructive<br />

Link Retry Test (#215) X X Nondestructive<br />