09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 18: Maintenance personnel have busied out the port in question. Release the<br />

port by using release port location.<br />

c. Error Type 130: The circuit pack has been removed or has been insane for more than<br />

21 minutes. To clear the error, reinsert or replace the circuit pack.<br />

d. Error Type 257: Problems transmitting to the voice terminal. This problem can be caused<br />

by defective wiring that can cause varying degrees of problems on different types of sets.<br />

Sets such as the 7410 appear to be more susceptible to wiring problems than others.<br />

e. Error Type 1537: There is a problem with the link to the voice terminal. This can be ignored<br />

if no user complaints are received. Otherwise, make sure the voice terminal is connected,<br />

check for defective wiring, check for a defective voice terminal, and move voice terminal to<br />

a jack that is closer to the switch (number of feet of wiring between the jack and the switch).<br />

If the problem still exists, replace the circuit pack. Once the problem has been resolved, the<br />

alarm is retired after a predetermined amount of time.<br />

f. Error Type 1793: The local loop test failed. Each failure increments an internal counter by 1<br />

when the local loop test fails. The counter is decremented when the loop test passes. When<br />

the counter reaches a threshold of 3, an on-board MINOR alarm is raised.<br />

g. Error Type 2049: The NPE Crosstalk test failed. The internal counter increments by 1 when<br />

the NPE Crosstalk test fails. The counter is decremented by 1 when the NPE Crosstalk test<br />

passes. When the counter reaches a threshold of 3, an on-board MINOR alarm is raised<br />

and the board is taken out of service.<br />

h. Error Type 2305: The station went off-hook while it was in the ready-for-service state. Use<br />

status station to determine the state of the station. The off-hook should have moved<br />

the station to ready-for-service. No action is necessary.<br />

i. Error Type 3840: No terminal is connected to the Digital Line board. No maintenance<br />

action is required.<br />

j. Error Type 3841: The circuit pack’s message buffer is full. This may be caused by having<br />

many display phones with heavy traffic connected to the circuit pack. No action is<br />

necessary.<br />

k. Error Type 2304: Internal system error. No action is necessary.<br />

776 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!