Communication Manager Maintenance Object Repair Procedures<br />

Error log entries and recommended actions<br />

Table 109: ADX16A-P Error Log Entries<br />

Error<br />

Type<br />

0 1<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended action<br />

0 Any Any Any test port location<br />

1 (a) 40977 None<br />

18 0 busyout<br />

station ext<br />

WRN ON release station extension<br />

23 (b) 0 None WRN OFF<br />

130<br />

(c)<br />

257<br />

(d)<br />

513<br />

(e)<br />

1025<br />

(f)<br />

40973 None<br />

Any None<br />

None WRN ON test port location<br />

Looparound Test<br />

(#161)<br />

1281 Conference Circuit<br />

Test (#7)<br />

1537 NPE Crosstalk Test<br />

(#6)<br />

MIN<br />

WRN 2<br />

ON test port location l r 2<br />

MIN ON test port location l r 2<br />

2<br />

WRN<br />

MIN ON test port location l r 2<br />

2<br />

WRN<br />

1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each<br />

appropriate test’s description, and follow its recommended procedures.<br />

2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.<br />

Notes:<br />

a. Error Type 1 is an inline error that can only be resolved over time. No terminal equipment<br />

was present when ringing was attempted. Execute test port location<br />

b. Error Type 23: The circuit pack was logically administered but not physically installed. The<br />

alarm will clear when the circuit pack is installed.<br />

c. Error Type 130: The circuit pack was removed or has been insane for more than<br />

11 minutes. To clear the error, reseat or replace the circuit pack.<br />