Communication Manager Maintenance Object Repair Procedures<br />

The CSU ELB (Equipment Loopback) test causes a loopback at the near-edge of the local 120A<br />

CSU module or T1 sync splitter, and tests the connection from the DS1 board to the CSU<br />

module/T1 sync splitter (DS1 board edge interconnecting cable, and CSU module/T1 sync<br />

splitter edge). This test will only be performed if the 120A CSU module/T1 sync splitter is<br />

present, administered, and connected to a 1.544-Mbps DS1 circuit pack on the back of the port<br />

carrier.<br />

The test is destructive and can only be initiated by entering the command<br />

test ds1-loop location ds1/csu-loopback-tests.<br />

Enter busyout board to busy out all trunks or ports on the DS1 Interface circuit pack before<br />

running the ELB test.<br />

When the ELB test is initiated, maintenance software sends a message to the DS1 Interface<br />

circuit pack to start the test. The board sets up the ELB loopback, transmits a test pattern, and<br />

verifies that the pattern is received unaltered through the loopback. If the transmitted and<br />

received pattern is different, the test fails.<br />

The DS1 circuit pack hardware applies a DC current while the test is running in order to detect<br />

any broken wires that may not be detected by the loopback pattern.<br />

When the test is complete, enter release board to restore all trunks or ports on the DS1<br />

Interface circuit pack to the in-service state.<br />

This test is run on the DS1-BD (DS1 Interface Circuit Pack) and UDS1-BD (UDS1 Interface<br />

Circuit Pack) maintenance objects.<br />

Table 578: CSU Equipment Loopback Test (#1210) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Enter test ds1-loop location ds1/csu-loopback-tests<br />

at 1-minute intervals up to 5 times.<br />

1005 ABORT CSU Equipment Loopback test cannot be executed in the current<br />

configuration. To run this test, the Near-End CSU Type field on the<br />

DS1 circuit pack administration screen must be set to integrated and the<br />

Bit Rate field must be set to “1.544” (for 24-channel operation).<br />

1. Enter change ds1 location and set the Near-End CSU Type<br />

field on the DS1 circuit pack administration screen to integrated,<br />

and/or set the Bit Rate field to 1.544 if the board is to be used in a<br />

24-channel configuration.<br />