FIBER-LK (Fiber Link)<br />

c. Error Type 18: the fiber link has been busied out via busyout fiber-link F P. To<br />

resolve this error, use release fiber-link F P to release the fiber link.<br />

d. Error Type 257: problem with the circuit path to the neighbor. See Repair procedures.<br />

e. Error Type 513: problem with the packet path to the neighbor. See Repair procedures.<br />

f. Error Type 769: problem with the control path from the neighbor. See Repair procedures.<br />

g. Error Type 1025: problem with the circuit path from the neighbor. See Repair procedures.<br />

h. Error Type 1281: problem with the packet path from the neighbor. See Repair procedures.<br />

Repair procedures<br />

For Note b and Notes d through h, perform the following steps:<br />

1. Perform the Fiber link fault isolation in Chapter 4: General troubleshooting in Maintenance<br />

Procedures (03-300432).<br />

2. Enter display errors and if any of the listed slip errors exist, follow the associated repair<br />

procedures in SYNC (Port Network Synchronization) for slip errors.<br />

Table 215: Error Log Entries for Slip Errors<br />

Circuit Pack Name Error Log Name Number of Slips<br />

DS1 Interface DS1-BD 3073 to 3160<br />

Expansion Interface EXP-INTF 2305<br />

SNI SNI-BD 1537<br />

Tone-Clock TDM-CLK 1025<br />

UDS1 Interface UDS1-BD 3073 to 3160<br />

Communication Manager Release 5.0 Issue 4 January 2008 837