Primary Signaling Link Hardware Check (#636)<br />

Primary Signaling Link Hardware Check (#636)<br />

This test runs on ATM-SGRP (ATM Signaling Group) and ISDN-SGR (ISDN-PRI Signaling<br />

Group).<br />

For ATM-SGRP, the ATM-SGRP Signaling Group D-channel port depends on the health of the<br />

TN230X interface circuit pack on which it resides. This test fails if there are problems with either<br />

the ATM-DCH (D-channel port) MO or the TN230X circuit pack. Investigate the ATM TN230X<br />

circuit pack ATM-TRK (Circuit Emulation Service Circuit Pack) anytime there are problems with<br />

the ATM D-channel port ATM-DCH (ATM D-Channel Port).<br />

For ISDN-SGR, the ISDN-PRI Signaling Group D-channel port depends on the health of the<br />

TN464 UDS1 Interface circuit pack or DS1 Interface Media Module on which it resides. This test<br />

will fail if there are problems with either the ISDN-PRI Primary D-channel port or the UDS1<br />

circuit pack or DS1 Media Module. If there are problems with the ISDN-PLK (ISDN-PRI<br />

Signaling Link Port), also investigate UDS1-BD (UDS1 Interface Circuit Pack) or MG-DS1 (DS1<br />

Interface Media Module).<br />

Table 521: Primary Signaling Link Hardware Check (#636) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1700 ABORT Rollabout video abort. The PRI terminal adapter associated with the<br />

primary D-channel port is detached from the circuit pack or media<br />

module. This is a normal abort when the rollabout video feature is<br />

enabled. To complete test on this port, either:<br />

1. Re-attach the disconnected PRI terminal adapter, or<br />

2. Enter change ds1 location to disable rollabout video on the<br />

board, and set the Alarm when PRI Endpoint Detached field to y.<br />