Table 569: VC DSP Port Local TDM Loopback Test (#1104) 2 of 3<br />

Error<br />

Code<br />

VC DSP Port Local TDM Loopback Test (#1104)<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS errors. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed<br />

65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the test. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) errors.<br />

3. Resolve any TONE-PT (Tone Generator) errors.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />

1004 ABORT The port is seized by a user for a valid call. Enter status station for<br />

the station associated with this port and determine whether the port is<br />

available for testing.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. If this result occurs repeatedly, attempt to reset the port with<br />

busyout port location, reset port location, and<br />

release port location.<br />

2. Rerun the test. If this result occurs again, replace the circuit pack.<br />

2012<br />

2100<br />

2103<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error.<br />

Could not allocate the necessary resources to run this test.<br />

The system could not make the conference connection for the test<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2 of 3<br />