Communication Manager Maintenance Object Repair Procedures<br />

Table 442: TDM Bus Clock Slip Inquiry Test (#149) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Any FAIL The Error Code represents the number of timing slips detected on the<br />

incoming synchronization source since the last slip inquiry was sent to the<br />

Tone-Clock circuit. The incoming synchronization signal can be from one<br />

of the following sources:<br />

1. A DS1 Interface circuit pack, if DS1 Synchronization is administered,<br />

and associated with the circuit pack tested<br />

2. S8700-series Fiber-PNC: A Stratum-3 clock, if that option is administered<br />

and the circuit pack tested was the active Tone-Clock in the PN 1.<br />

3. S8700-series Fiber-PNC: The local oscillator on the master IPSI’s<br />

Tone-Clock circuit or on the master Tone-Clock circuit pack, if it is<br />

providing the PN’s clocking signals<br />

4. S8700-series IP-PNC: The local oscillator on the IPSI’s Tone-Clock circuit<br />

providing the media gateway’s clocking signals<br />

5. S8700-series Fiber-PNC: An EXP-INTF circuit pack, if the PN on which<br />

the test was executed does not contain the system’s current<br />

synchronization reference<br />

The Error Code is a value between 1 and 255.<br />

1. Small numbers of slips should not result in service degradation. If the<br />

Error Code is small (1 or 2), rerun the test. If the error only occurs<br />

infrequently, it may be ignored.<br />

2. Otherwise, see Synchronization Troubleshooting in SYNC (Port<br />

Network Synchronization).<br />

PASS The IPSI or Processor/Tone-Clock circuit pack does not detect any timing<br />

slips. This indicates that the incoming synchronization timing source is valid<br />

or that the system’s synchronization reference is an IPSI or Processor/<br />

Tone-Clock circuit pack. Enter status synchronization to verify that<br />

the desired synchronization reference is providing timing for the system.<br />

TDM Bus Clock PPM Inquiry Test (#150)<br />

This test evaluates the quality of the synchronization source for the Tone-Clock circuit.<br />

This test runs on the following maintenance objects:<br />

1618 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />