Table 538: Packet Neighbor Link Test (#767) 4 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Packet Neighbor Link Test (#767)<br />

123 FAIL The SNI circuit pack cannot communicate with its neighbor using the<br />

packet path.<br />

1. Fix any on-board errors (SNI-BD, EXP-INTF, and/or DS1C-BD)<br />

against the components of this fiber link by using display errors<br />

and display alarms and following the repair procedures. Enter<br />

list fiber-link to find the fiber link associated with this SNI.<br />

Enter display fiber-link to find the endpoints of the fiber link<br />

and the DS1C circuit pack locations if this fiber link has a DS1<br />

Converter complex administered.)<br />

2. Enter display errors and display alarms and follow the repair<br />

procedures for any SNC-BD error entries with corresponding<br />

on-board alarm entries.<br />

3. Enter display errors and follow the repair procedures for any<br />

SYNC entries.<br />

4. If this FIBER-LK has circuit, packet, and control path errors, check the<br />

lightwave transceiver connections or metallic connections. Enter the<br />

LED states to verify whether the connections are correct. Also, a test<br />

fiber-links command can be run to determine whether a fiber out of<br />

frame condition exists on the fiber link. The SNI Fiber Out of Frame<br />

Query Test (#989) reports whether a fiber out of frame condition exists<br />

for an SNI endpoint, and the Expansion Interface Fiber Out-of-Frame<br />

Query Test (#238) reports whether a fiber out of frame condition exists<br />

for an Expansion Interface endpoint.<br />

5. Replace the lightwave transceivers if present.<br />

6. Replace one of the endpoint boards.<br />

7. Replace the other endpoint board.<br />

8. Replace the DS1 converter circuit packs if a DS1 converter complex<br />

is administered on this fiber.<br />

PASS The SNI can communicate with the peer SNIs and the neighbor over the<br />

packet path.<br />

4 of 5<br />