Communication Manager Maintenance Object Repair Procedures<br />

By making translation and cross-connect changes, circuit packs (except for TN497) can be<br />

configured for back-to-back testing, also known as connectivity testing. Port operation is tested<br />

by connecting two tie trunk ports together in either E&M or simplex modes. See the section<br />

Analog tie trunk back-to-back testing in Maintenance Procedures (03-300432).<br />

Error log entries and recommended actions<br />

Table 359: TIE-TRK Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test port location<br />

1 (b) 16384 WRN OFF<br />

1 (c) 57476 WRN OFF<br />

1 (d) 57477 WRN OFF<br />

1 (e) 57483 WRN OFF<br />

1 (f) 57485 WRN OFF<br />

15 (g) Any Port Audit and Update<br />

test (#36)<br />

18 (h) 0 busyout trunk<br />

grp#/mem#<br />

WRN OFF release trunk grp#/mem#<br />

130 (i) WRN ON test trunk grp#/mem#<br />

257 (j) 57473 WRN OFF<br />

257 (k) 57474 WRN OFF<br />

257 (l) 57475 WRN OFF<br />

513 (m) Any EPF M and E Lead<br />

(#74)<br />

769 (m) 57481 EPF M and E Lead<br />

(#74)<br />

MAJ<br />

MIN<br />

WRN 1<br />

MAJ<br />

MIN<br />

WRN 1<br />

1025 (n) Any None MAJ<br />

MIN<br />

WRN 1<br />

OFF test port location r 3<br />