Communication Manager Maintenance Object Repair Procedures<br />

If there are any M/T-DIG errors in the Error Log, see M/T-BD (Maintenance/Test Circuit Pack)<br />

and clear them first.<br />

This test will pass regardless of any customer equipment that may be connected to the port, as<br />

long as the equipment is not using the port.<br />

This test runs on DAT-LINE (Data Line Port).<br />

Table 453: Digital Looparound Test (#171) 1 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run test are not available. The port may be<br />

in use on a valid call. Enter status data-module to determine when<br />

the port is available for testing.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1005<br />

1007<br />

ABORT Data Channel 3 is not administered. This port is required to run this test.<br />

1. Verify that data channel 3 is not administered with<br />

list data-module.<br />

2. Administer data channel 3 with add data-module, and run this test<br />

again.<br />

1016 ABORT Data Channel 3 is busy. The port may be in use on a valid call. Enter<br />

status data-module to determine when the port is available for<br />

testing.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

1020 ABORT An existing Error Type #769 on this port prevented the test from running.<br />

1. Follow the procedure described in the Error Log Table for Error Type<br />

#769 for this maintenance object.<br />

1042 ABORT The port under test is a TTI port and has only default translations with no<br />

assigned extension. The test requires an assigned extension associated<br />

with the port being tested.<br />

1. If there is a need to run the test on this particular port, verify that the<br />

port is fully translated and has an assigned extension.<br />

1632 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 4