Communication Manager Maintenance Object Repair Procedures<br />

Notes:<br />

a. Error Type 0: a Digital Line circuit pack that has ports administered has been removed<br />

since the Error Log was last cleared. Make sure that the circuit pack has been re-inserted.<br />

b. Error Type 1, Aux Data 40987: an off-board problem was detected by the port circuit, and<br />

may result in a noisy port or link. See Note (n) for recommendations.<br />

Note: Refer<br />

Note: Refer<br />

Note: Refer<br />

Note: Refer<br />

Note:<br />

to the DEFINITY® Communications System Generic 1 and Generic 3i<br />

Wiring, 555-204-111.<br />

c. Error Type 1, Aux Data 1 - 20 is logged when at least 15 off-board problems have been<br />

detected with the link to the data module. Each error detected increments an on-board<br />

counter. The aux data gives the value of this counter divided by 15. The user could<br />

experience a noisy port or link. See Note (n) for recommendations.<br />

Note:<br />

to the DEFINITY® Communications System Generic 1 and Generic 3i<br />

Wiring, 555-204-111.<br />

d. Error Type 15: an internal error that occurs when an audit request fails.<br />

e. Error Type 18: the port in question is demand busied out. Release the port with<br />

release port location.<br />

f. Error Type 257: problems with transmitting to the data module. This is usually an on-board<br />

problem and can be ignored if no user complaints are received. Otherwise, check for faulty<br />

wiring.<br />

g. Error Type 769: EPF has been turned off due to the overcurrent condition at the data<br />

module. See the recommendations in note n. This may also be caused by the PTC being in<br />

the “tripped” position due to a short on the power line. You can correct this by removing the<br />

short, unplugging the data module from the wall for about 30 seconds, and plugging it back<br />

in.<br />

Note:<br />

to the DEFINITY® Communications System Generic 1 and Generic 3i<br />

Wiring, 555-204-111.<br />

h. Error Type 1537: there is a problem with the link to the data module. This can be ignored if<br />

no user complaints are received. Otherwise, see Note (n) for recommendations.<br />

Note:<br />

to the DEFINITY® Communications System Generic 1 and Generic 3i<br />

Wiring, 555-204-111.<br />

i. Error Type 2304: internal error. No action is necessary.<br />

j. Error Type 2305, Aux Data 32770: the data equipment went off-hook while the associated<br />

link was being initialized (in a disconnected state). Use status data-module to<br />

determine the state of the data module. The off-hook should have changed the service state<br />

to in-service. No action is necessary.<br />