ADX16A-P (AUDIX Analog Line/Control Link)<br />

d. Error Type 257 is an inline error and can only be resolved over time. Ringing voltage is<br />

absent. If only one analog circuit pack in the system has this problem, replace the circuit<br />

pack. If only analog circuit packs on a particular carrier have this error, the ringing generator<br />

may not be connected to this carrier. If analog circuit packs on many carriers have this error,<br />

check the ringing generator.<br />

e. Error Type 513: AUDIX is not available to the switch. Check the AUDIX system, referring to<br />

DEFINITY® AUDIX Maintenance, 585-300-110.<br />

f. Error Type 1025: The TDM bus is out of service. See TDM-BUS (TDM Bus).<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Tests 36 and 48 ABORT when AUDIX is not running.<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Analog Looparound Test (#161)) X ND<br />

Conference Circuit Test (#7) X ND<br />

NPE Crosstalk Test (#6) X ND<br />

1. D = Destructive; ND = Nondestructive<br />

Communication Manager Release 5.0 Issue 4 January 2008 439