Communication Manager Maintenance Object Repair Procedures<br />

Table 384: Local Loop Test (#13) 6 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

7 FAIL The Conference Test failed on the primary channel.<br />

M/T-ANL:<br />

1. Check the Tone Clock and the Tone Detector circuit packs by<br />

entering test board location for these circuit packs.<br />

2. Resolve any problems detected on the Tone-Clock or Tone Detector<br />

circuit pack and retest.<br />

3. If the Tone Clock and Tone Detector circuit packs are functioning<br />

properly and the test still fails, replace the Maintenance/Test circuit<br />

pack.<br />

For all other Maintenance Objects:<br />

1. Check the Tone Generator and the Tone Detector circuit packs by<br />

entering test board location for these circuit packs.<br />

2. Resolve any problems detected on the Tone Generator and Tone<br />

Detector circuit packs and retest.<br />

3. If the Tone Generator and Tone Detector circuit packs are<br />

functioning properly and the test still fails:<br />

ADX8D-PT and ADX16D-P: Shut down AUDIX and replace the<br />

EMBEDDED AUDIX circuit pack.<br />

DIG-LINE, E-DIG-ST, PDMODULE, and TDMODULE: Replace<br />

the Digital Line circuit pack.<br />

M/T-DIG: Replace the Maintenance/Test circuit pack.<br />