SVC-SLOT (Service Slot)<br />

SVC-SLOT (Service Slot)<br />

MO Name Alarm Level Initial Command to Run Full Name of MO<br />

SVC-SLOT MIN none Service Slot<br />

The Service Slot MO detects the insertion of an invalid circuit pack into a dedicated SERVICE<br />

slot. The SERVICE slot is the left-most slot in the J58890BB port carrier, and is identified as slot<br />

location “00” in commands and screen fields.<br />

Because this slot does not provide tip and ring connectivity to the wall field, only the following<br />

circuit packs are allowed:<br />

● TN744 Call Classifier<br />

● TN750 Integrated Announcement<br />

● TN771 Maintenance/Test<br />

● TN725 Speech Synthesizer<br />

● TN433 Speech Synthesizer<br />

● TN457 Speech Synthesizer<br />

● TN748 Tone Detector<br />

● TN420 Tone Detector<br />

When another circuit pack is inserted in a SERVICE slot, a MINOR alarm is generated against<br />

the Service Slot MO. Instead of the illegal circuit pack’s MO name, the “Service Slot” MO name<br />

is used to prevent any attempt to assign a port to the illegal pack physically residing in the<br />

SERVICE slot.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1251