CLSFY-PT (Call Classifier Port)<br />

CLSFY-PT (Call Classifier Port)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

CLSFY-PT MAJ<br />

MIN<br />

WRN<br />

The TN744 Call Classifier is a service circuit pack that provides specialized tone detection<br />

capabilities to support the Outbound Call Management (OCM) and Inbound Call Management<br />

(ICM) features. The TN744 supports both A-law and Mu-law companding.<br />

The TN744 has eight ports (CLSFY-PTs), each capable of supporting call classification,<br />

touch-tone reception and MFC-tone generation and detection. The CLSFY-PT MO implements<br />

a set of tests designed to ensure proper operation of the Call Classifier.<br />

Error log entries and recommended actions<br />

Table 169: CLSFY-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm Level On/Off<br />

Board<br />

test port location Call Classifier Port<br />

Recommended Action<br />

1 any Tone Detector Audit/<br />

Update Test (#43)<br />

MAJ / MIN (a) ON test port location r 2<br />

18 busyout port WRN OFF release port location<br />

257 (b) 17666 Tone Detector Audit/<br />

Update Test (#43)<br />

513 (c) any Tone Detection<br />

Verification Test<br />

(#42)<br />

MAJ / MIN (a) ON test port location r 3<br />

MAJ / MIN (a) ON test port location r 3<br />

Notes:<br />

a. A major alarm is raised if the total number of call classifier ports currently in-service is less<br />

than or equal to 1/2 of the administered threshold number. For major or minor alarm, run the<br />

short test sequence on the alarmed port and follow the error code procedures for the<br />

individual tests.<br />

The in-service threshold number for alarming call classifier ports is administered using the<br />

change system-parameters maintenance.<br />

1. Enter these commands in order: busyout board, reset board, release board.<br />

The board reset is required to reload on-board RAM associated with the TN744’s DSPs.<br />

This takes all 8 Tone Detector ports out of service for a few seconds. Only 4 of the 8<br />