09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

Table 443: TDM Bus Clock PPM Inquiry Test (#150) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

TDM Bus Clock PPM Inquiry Test (#150)<br />

ABORT The system could not allocate the necessary resources for the test<br />

1. Wait 1-minute, then retry the test.<br />

1001 ABORT The system could not allocate the necessary resources for the test.<br />

1. Wait 1-minute, then retry the test.<br />

255 ABORT The test was not executed because the IPSI or Processor/Tone-Clock<br />

circuit pack was using its local oscillator rather than synchronizing to an<br />

external source.<br />

1. Verify that this IPSI or Processor/Tone-Clock circuit pack is expected<br />

to be the synchronization source. If not, correct the synchronization<br />

information and re-run the test.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2100 System resources required to run this test are not available.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

Any FAIL The Error Code represents the rate (in Parts Per Million, or PPM) at<br />

which clock slip errors have been detected on the incoming<br />

synchronization source since the last PPM inquiry was sent to the IPSI<br />

or Processor/Tone-Clock circuit pack. A failure of this test indicates that<br />

we are outside of (S8700-series Fiber-PNC: Stratum-3) or Stratum-4 timing<br />

specifications on the incoming timing source.<br />

The Error Code is a variable amount ranging from 1 to 254.<br />

1. If error 1537 is entered in the error log against TDM-CLK, then the<br />

board has switched timing sources. Follow the procedures<br />

associated with hardware log Error Code 1537.<br />

2. Otherwise, see Troubleshooting Approach in SYNC (Port Network<br />

Synchronization).<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1619