Communication Manager Maintenance Object Repair Procedures<br />

Steady State LEDs<br />

The LEDs of PNC components in a stable duplicated system should appear as follows:<br />

● For an active ATM EI (functioning as Archangel) in a PN without IPSIs, the amber LED’s<br />

flash pattern is 2 seconds on/200 ms off.<br />

● For a standby ATM EI in a PN without IPSIs, the amber LED is off.<br />

● For an active ATM EI in a PN with IPSIs, the amber LED is on steady.<br />

● For an standby ATM EI in a PN with IPSIs, the amber LED is off.<br />

PNC State of Health<br />

PNC-DUP software monitors the health of the two PNCs as determined by their state-of-health<br />

(SOH) vectors, and initiates an interchange when the health of the active falls below that of the<br />

standby (unless prevented from doing so by a PNC lock, busyout, or antithrashing mechanism).<br />

Potentially service-disrupting faults that occur in a PNC’s components are reported to<br />

PNC-DUP and incorporated in the affected PNC’s state of health. The SOHs of both PNCs are<br />

displayed on the status pnc screen, as shown in Figure 37: Status PNC screen with standby<br />

PNC fully In-Service.<br />

Figure 37: Status PNC screen with standby PNC fully In-Service<br />

status pnc page 1 of 1<br />

PORT-NETWORK CONNECTIVITY<br />

Duplicated? yes<br />

Software Locked? no<br />

Standby Busied? no<br />

Standby Refreshed? yes<br />

Interchange Disabled? no<br />

A-PNC B-PNC<br />

Mode: active Mode: standby<br />

State of Health: functional State of Health: functional<br />

Inter PN Index: 00.00.00.00 Inter PN Index: 00.00.00.00<br />

Major <strong>Alarms</strong>: 0 Major <strong>Alarms</strong>: 0<br />

Minor <strong>Alarms</strong>: 0 Minor <strong>Alarms</strong>: 0<br />

Warning <strong>Alarms</strong>: 0 Warning <strong>Alarms</strong>: 0<br />

538 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s