Communication Manager Maintenance Object Repair Procedures<br />

4. If the PN’s LEDs are lit and there are multiple fibers to the distant switch node, remove the<br />

SNC that is listed by list fiber-link for this path.<br />

If the PN’s LEDs are not lit, enter list fiber-link to verify that the fiber connections to<br />

the PN are consistent with the administration assignments.<br />

5. Enter status sys-link to determine the new path from the IPSI connected PN to the<br />

distant switch.<br />

6. Run test led port-network on the port network connected to the distant switch node,<br />

and verify that the LEDs on the correct PN are lit.<br />

7. Repeat steps 4 – 6 until every SNI-to-SNI fiber connection to the distant switch has been<br />

tested.<br />

FIBER-LK Error codes and recommended actions<br />

The following table contains the error codes and recommended actions for FIBER-LK (Fiber<br />

Link).<br />

Table 533: FIBER-LK Configuration Audit (#759) 1 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

2300 The downlink message necessary to run this test could not be sent.<br />

2301 The timer could not be set before sending the downlink message.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

1810 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 9