UDS1-BD (UDS1 Interface Circuit Pack)<br />

Note:<br />

Note: Set the Echo Cancellation Plan on the EC Configuration field of the DS1<br />

Circuit Pack screen. Note that Plan 1 uses a 96-ms echo tail and introduces 6dB<br />

of loss for additional cancellation.<br />

In addition, other fields define such parameters as framing modes, line coding, companding<br />

mode and so on. For further details refer to Installing and Operating a 120A Channel Service<br />

Unit with <strong>Avaya</strong> Communication Manager (03-601508).<br />

Two option jumpers located on the side of the TN464C/D circuit pack must be installed correctly.<br />

The figures on the following page show how to configure the circuit pack for 24- or 32-channel<br />

DS1, and for 75*W (coaxial) or 120*W trunk connections. The channel selection must match the<br />

parameters administered on the corresponding DS1 Circuit Pack screen. (US applications use<br />

24 Channels.)<br />

Figure 128: TN464C/D DS1 Option Jumpers<br />

TN464C/D<br />

Backplane Connectors<br />

24/32 Channel Selector<br />

Figure 129: TN464C/D DS1 Option Jumpers (cont’d)<br />

24 CHNL<br />

32 CHNL<br />

120 OHM<br />

75 OHM<br />

Top<br />

Bottom<br />

75/120 Ohm Selector<br />

Faceplate<br />

Insert the jumpers into the blocks<br />

so as to join the center row of<br />

pins and the row designating the<br />

desired options.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1385