Communication Manager Maintenance Object Repair Procedures<br />

The DS1 circuit pack, combined with the 120A CSU module or the 401A T1 sync splitter, forms<br />

an Integrated CSU (ICSU).<br />

If the 120A CSU module/T1 sync splitter is not installed, the status LEDs are always off and this<br />

test aborts.<br />

This test is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 585: ICSU Status LEDs Test (#1227) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT The ICSU Status LEDs test cannot be executed for the current<br />

configuration. The test applies only to TN767E or later DS1 circuit packs<br />

and TN464F or later UDS1 circuit packs administered for 24-channel<br />

(1.544-Mbps) operation.<br />

1. If the circuit pack is of the correct type, retry the command.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

1951 ABORT The ICSU Status LEDs Test cannot be executed because a 120A CSU<br />

module or a 401A T1 sync splitter is not physically installed. If using a<br />

120A CSU module/T1 sync splitter, physically connect it to the TN767 or<br />

TN464 board on the back of the port carrier. Otherwise, ignore this abort.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />