09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

This test runs on M/T-DIG (Maintenance/Test Digital Port).<br />

Table 492: Digital Port Sanity Test (#565) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT One of the digital ports is busy with background maintenance.<br />

1. Either wait for the port to become idle, or busyout both Maintenance/<br />

Test digital ports on the Maintenance/Test circuit pack with busyout<br />

port location (02) and busyout port location (03).<br />

2. If the ports were busied out, release them with release port<br />

location (02) and release port location (03).<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

4. If the test continues to abort, escalate the problem.<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS errors. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy traffic,<br />

retry the command at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid ISDN-PRI test call.<br />

1. Enter list isdnpri-testcall to determine which call is using the<br />

port from the M/T Port column. Wait for the test call to complete as<br />

indicated in the Start Time and Duration fields, or abort the test call<br />

with clear isdnpri-testcall grp#/mem#, where grp#/mem#<br />

is determined from the B-Channel field of<br />

list isdnpri-testcall.<br />

2. Rerun the test.<br />

1718 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />