Error log entries and recommended actions<br />

Table 309: POW-SUP Error Log<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level 1<br />

1 (a) Any Power supply detection test<br />

(#1535)<br />

23 (b)<br />

257 (c)<br />

513 (d)<br />

769 (e)<br />

1025 (f)<br />

1281 (g)<br />

Power supply detection test<br />

(#1535)<br />

Power supply recycle test<br />

(#1534)<br />

Power supply voltage test<br />

(#1536)<br />

Power supply voltage test<br />

(#1536)<br />

Power supply voltage test<br />

(#1536)<br />

Power supply voltage test<br />

(#1536)<br />

1537 (h) Any Power supply detection test<br />

(#1535)<br />

1793 (i) Any Power supply detection test<br />

(#1535)<br />

2049 (j)<br />

2305 (k)<br />

Power supply detection test<br />

(#1535)<br />

Power supply aux sig test<br />

(#1649)<br />

MAJ<br />

MIN<br />

On/Off<br />

Board<br />

Notes:<br />

a. Error Type 1: power supply not detected.<br />

b. Error Type 23: the power supply is administered, but not present.<br />

1. Verify that the power is plugged in.<br />

2. Check the yellow LED to determine that the power is on.<br />

POW-SUP (Power Supply)<br />

Recommended Action<br />

ON test environment location<br />

test board location<br />

WRN ON test board location<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

MIN<br />

WRN<br />

MAJ<br />

MIN<br />

ON recycle carrier location [override]<br />

ON test environment location<br />

test board location<br />

ON test environment location<br />

test board location<br />

ON test environment location<br />

test board location<br />

ON test environment location<br />

test board location<br />

ON test board location<br />

ON test board location<br />

ON test board location<br />

ON test board location<br />

1. This is a MINOR alarm if there is a redundant power supply, and a MAJOR alarm if there is only one power<br />