Table 386: Digital Station Audits Test (#17) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Digital Station Audits Test (#17)<br />

3 ABORT The EPF has detected an overcurrent condition<br />

DIG-LINE:<br />

1. For a TN754 vintage 13 or earlier Digital Line circuit pack, enter<br />

test port location long.<br />

● If Test #11 passes, the EPF condition was cleared. Rerun the<br />

short test sequence.<br />

● If Test #11 does not pass, follow the repair procedures for Digital<br />

Line Electronic Power Feed Test (#11)<br />

2. Look for Error Type 769 logged against DIG-LINE and follow the<br />

procedures for DIG-LINE (Digital Line).<br />

3. Rerun the test.<br />

RDIG-STA:<br />

1. Enter test port location long.<br />

● If Test #11 passes, the EPF condition was cleared. Rerun the<br />

short test sequence.<br />

● If Test #11 does not pass, follow the repair procedures for Digital<br />

Line Electronic Power Feed Test (#11).<br />

2. Look for Error Type 769 logged against RDIG-STA and follow the<br />

procedures for RC-BD (Radio Controller Board).<br />

3. Rerun the test.<br />

4 ABORT Internal system error<br />

1. Resolve any outstanding circuit pack or media module maintenance<br />

problems.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

2 of 4<br />

Communication Manager Release 5.0 Issue 4 January 2008 1477