Communication Manager Maintenance Object Repair Procedures<br />

SNI Sanity Timer Test (#964)<br />

The SNI Sanity Timer Test checks the number of times the sanity timer has expired. If the sanity<br />

timer expires twice within one second, the SNI will lock up and port networks will go down. The<br />

test passes if there are no sanity timer expirations. The test fails if it detects that the SNI has<br />

missed sanity. This test runs on SNI-BD (SNI Circuit Pack).<br />

Table 564: SNI Sanity Timer Test (#964) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2000 ABORT The response to a query was not received in the time allowed.<br />

1. Repeat the command at one-minute intervals 1 to 3 times.<br />

2073 ABORT The firmware on the SNI circuit pack is invalid.<br />

1. Escalate the problem.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this test could not be sent.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2301 ABORT The software timer could not be set before sending the downlink message.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2302 ABORT A bad uplink message was received.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

FAIL The test detected that the SNI missed sanity.<br />

1. Escalate the problem.<br />

PASS No problems are detected on the board.<br />