Communication Manager Maintenance Object Repair Procedures<br />

Table 384: Local Loop Test (#13) 2 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT Could not seize the port. The port may be busy with a valid call.<br />

ADX8D-PT, ADX16D-P, DIG-LINE and E-DIG-ST:<br />

1. Enter display port location to determine the station<br />

extension or attendant number of the port.<br />

2. Enter status station extension or status attendant<br />

extension to determine the service state of the port. If the port is<br />

in use, wait until it is idle before retesting. Attendants are always in<br />

use (off-hook) if the handset is plugged in and the port is not busied<br />

out.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

M/T-ANL:<br />

1. To determine whether the port is in use by a valid ATMS test call,<br />

enter status station ext where ext is the assigned ATMS<br />

station’s number.<br />

2. If the port is in use, wait until it is idle.<br />

3. Retry the command at 1-minute intervals up to 3 times.<br />

M/T-DIG:<br />

1. Enter list isdnpri-testcall to determine which call is using<br />

the port. Wait for the test call to complete as indicated in the Start<br />

Time and Duration fields, or abort the test call with clear<br />

isdnpri-testcall grp#/mem#, where grp#/mem# is<br />

determined from the B-Channel field of list<br />

isdnpri-testcall.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

PDMODULE and TDMODULE:<br />

1. Enter display port location to determine the data module<br />

extension.<br />

2. Enter status data module extension to determine the<br />

service state of the data module. If the service state indicates that<br />

the data module is in use, wait until the port is idle before retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1001 ABORT System resources required to run this test are not available.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />