XXX-BD (Common Port Circuit Pack/Media Module)<br />

k. Error Type 1025: this error is not service-affecting and no action is required.<br />

l. Error Type 1281: no ringing current is detected. Run Test #51, Ringing Application Test,<br />

and follow the procedures for Ringing Application Test (#51).<br />

m. Error Type 1412: Test is not applicable to media modules or gateways. This error can be<br />

ignored. No action is necessary.<br />

n. Error Type 1538: the hyperactive circuit pack or media module is out-of-service and may<br />

exhibit one or more of the following symptoms:<br />

1. The common circuit pack/media module level tests such as Test #51 and/or Test #220<br />

are aborting with Error Code 2000.<br />

2. The tests run on the ports of this circuit pack or media module are returning with a<br />

NO-BOARD.<br />

3. A busyout/release of the circuit pack or media module has no effect on test results.<br />

4. A list configuration command shows that the circuit pack or media module and<br />

ports are properly installed.<br />

If the XXX-BD is not a TN754 Digital Line Circuit Pack (DIG-BD) or Digital Line Media<br />

Module, and if this error happens again within 15 minutes, then replace the circuit pack or<br />

media module. If the XXX-BD is a TN754 Digital Line Circuit Pack (DIG-BD) or Digital Line<br />

Media Module, then check the alarm level. If the alarm level is a WARNING, this indicates<br />

that users are probably causing the hyperactivity by adjusting or changing their digital<br />

stations. If the circuit pack or media module is very hyperactive, then this alarm will be<br />

upgraded to a MINOR alarm within 1 hour. If the alarm level is a MINOR alarm, then replace<br />

the circuit pack or media module.<br />

o. Error Type 1793: no neon current is detected. Run test board location and follow<br />

the procedures for Neon Test (#220).<br />

p. Error Type 3840: this error is not service-affecting and no action is required.<br />

q. Error Type 3999: the circuit pack or media module sent a large number of control channel<br />

messages to the switch within a short period of time. If Error Type 1538 is also present, then<br />

the circuit pack or media module was taken out-of-service due to hyperactivity. If Error Type<br />

1538 is absent, then the circuit pack or media module was not taken out-of-service, but it<br />

has generated 50% of the messages necessary to be considered hyperactive. This may be<br />

completely normal during heavy traffic periods. However, if this Error Type is logged when<br />

the circuit pack or media module is being lightly used, it may indicate a problem with the<br />

circuit pack or media module, or the equipment attached to it.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1427