Communication Manager Maintenance Object Repair Procedures<br />

Table 533: FIBER-LK Configuration Audit (#759) 7 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

212 FAIL The SNI circuit pack cannot communicate with the active SNC.<br />

1. Check the error log for other SNI circuit packs in the same carrier with<br />

an SNI-BD error for Error Type 257. Enter display errors with<br />

category PNC to view SNI-BD errors. If other SNI circuit packs in the<br />

same switch node carrier have error 257, then replace the active SNC<br />

in this switch node carrier. Replacing an SNC may be service<br />

interrupting. Refer to SNC-BD (Switch Node Clock Circuit Pack) for<br />

the procedure for replacing an SNC.<br />

2. Replace this SNI. Refer to SNI-BD (SNI Circuit Pack) for the<br />

procedure.<br />

3. Replace the active SNC in the same switch node carrier.<br />

233 FAIL No neighbor link is assigned, but the SNI (Endpoint 2) has an EI neighbor.<br />

1. Enter list fiber-link to display a fiber link’s endpoints.<br />

If the SNI should have an EI neighbor:<br />

1. Enter add fiber-link next to assign the fiber link’s SNI to its<br />

physically connected EI neighbor.<br />

If not:<br />

2. Remove both fiber endpoints (i.e., this SNI and its EI neighbor).<br />

3. Enter change circuit-pack to remove the fiber endpoints from<br />

circuit-pack administration.<br />

234 FAIL No neighbor link is administered, but the SNI (Endpoint 2) has an SNI<br />

neighbor.<br />

1. Enter list fiber-link to display a fiber link’s endpoints.<br />

2. Administer the SNI on a fiber link to the SNI neighbor it is connected<br />

to via add fiber-link next. Or remove both fiber endpoints (i.e.,<br />

this SNI and its SNI neighbor) and remove the fiber endpoints from<br />

circuit pack administration via change circuit-pack.<br />

1816 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />