Table 189: DS1 Facility Line Signal Equalization Values 2 of 2<br />

DS1 Converter-1 and<br />

DS1 Converter-2 Line<br />

Compensation<br />

(cont’d)<br />

Equalizer<br />

Setting<br />

Distance to Network Interface (feet)<br />

Cable type 22 AWG ABAM &<br />

24 AWG PDS<br />

3 266 to 399 180 to 270<br />

4 399 to 533 270 to 360<br />

5 533 to 655 360 to 450<br />

DS1 Converter Performance Measurements Report<br />

DS1-FAC (DS1 Facility)<br />

Cable type 26<br />

AWG PDS<br />

2 of 2<br />

The DS1 Converter Performance Measurements provide link performance measurements for<br />

the DS1 facilities.<br />

When no facility alarms exist on the DS1 facility, events that indicate a degradation in the<br />

performance of the DS1 facility are monitored and recorded. These events will generate alarms<br />

when performance of the DS1 facility has degraded below acceptable levels. These<br />

measurements include errored seconds, bursty seconds, severely errored seconds, and failed<br />

seconds.<br />

There are two DS1 Converter Performance Measurements Sub-reports:<br />

● The DS1 Converter Performance Measurements Summary Report provides information<br />

about the worst 15-minute interval of data, the total for 24 hours of data and the current<br />

15-minute counter for each of the previously mentioned counters.<br />

● The DS1 Converter Performance Measurements Detailed Report displays a detailed log<br />

for the last 96 15-minute intervals for each of the previously mentioned counters.<br />

Access the DS1 Converter Performance Measurements Summary Report with list<br />

measurements ds1-facility summary location [print | schedule]. Access a<br />

more detailed version of the report with list measurements ds1-facility log<br />

location f [print | schedule].<br />

You can reset every hardware- and software-measurement counter for a given facility with<br />

clear measurements ds1-facility location f. The Counted Since time is also<br />

reset and the Number of Valid Intervals count is set to zero.<br />

The reports are printed on the screen or, by using the print option, on a printer attached to the<br />

terminal.<br />