DIOD-DS1 (DS1 DIOD Trunk)<br />

DIOD-DS1 (DS1 DIOD Trunk)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

DIOD-DS1 MAJ 1<br />

MIN<br />

WRN test trunk grp#/mem#<br />

1. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

and that at least 75 percent of the trunks in this trunk group are alarmed.<br />

Note:<br />

Note: Many trunk problems are caused by incorrect settings of parameters on the trunk<br />

group administration screen. Settings must be compatible with the local<br />

environment and with parameter settings on the far end. Refer to Administrator<br />

Guide for <strong>Avaya</strong> Communication Manager, 03-300509 for information on how to<br />

administer trunks. Refer to your <strong>Avaya</strong> representative for the correct settings for<br />

administrable timers and other parameters on a country-by-country basis.<br />

A DS1 Direct Inward Outward Dialing (DIOD) trunk provides a link for digitized voice or data<br />

communications between the system and a central office switch. There are two types of DS1<br />

interfaces:<br />

● 24 DS0 channels on a 1.544-Mbps link<br />

● 31 DS0 channels + 1 framing channel on a 2.048-Mbps link<br />

test trunk grp#/mem# l DS1 DIOD Trunk<br />

Note:<br />

Note: 32-channel mode is supported only on TN464C and higher suffix circuit packs.<br />

The DS1-DIOD MO monitors and maintains a DIOD trunk port on a TN464 UDS1 Interface<br />

circuit pack. See UDS1-BD (UDS1 Interface Circuit Pack) for more information about this circuit<br />

pack. The DS1 circuit pack supports low-level CO trunk signaling interfaces for both<br />

ground-start and loop-start trunks. This maintenance strategy covers the inline errors log,<br />

initialization tests, periodic tests, scheduled tests, demand tests, and alarm resolution and<br />

escalation.<br />

Three trunk service states are specified by DS1 DIOD trunk maintenance:<br />

out-of-service The trunk is in a deactivated state and cannot be used for either<br />

incoming or outgoing calls.<br />

in-service The trunk is in an activated state and can be used for both incoming<br />

and outgoing calls.<br />

disconnect<br />

(ready-for-service)<br />

The trunk is in an activated state but can only be used for an<br />

incoming call.<br />