Communication Manager Maintenance Object Repair Procedures<br />

PPP Link Status Inquiry Test (#1279)<br />

The PPP Link Status Inquiry Test determines the state of the PPP link. The test passes only if<br />

the link is up.<br />

This test runs on PPP-PT (Control LAN Packet/Port).<br />

Table 598: PPP Link Status Inquiry Test (#1279) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1124 ABORT PPP link is not enabled.<br />

1. Verify that the PPP link is enabled with status port location,<br />

status link n, or display data-module.<br />

2. If the link is not enabled, enable the link with change data-module<br />

3. Repeat the test.<br />

1125 ABORT PPP Link is not in service.<br />

1. Verify whether PPP link is in-service with status port location<br />

or status link n.<br />

2. If the PPP link is not in service, release the link with<br />

release link n or release port location<br />

3. Repeat the test.<br />

2100 ABORT Could not locate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />