Communication Manager Maintenance Object Repair Procedures<br />

This test runs on PPP-PT (Control LAN Packet/Port) and VAL-PT (Voice Announcements over<br />

LAN Packet/Port).<br />

Table 596: SCOTCH Synchronous Looparound Test (#1275)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT The port is in use.<br />

1. Retry the command when the port is idle, or use busyout port<br />

location to force the port to the idle state.<br />

Note: This command is destructive, causing every call and link using the<br />

port to be torn down.<br />

1002 ABORT No TDM bus time slots available for the test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

1963 ABORT The port is in use.<br />

1. Retry the command when the port is idle, or use busyout port<br />

location to force the port to the idle state.<br />

Note: This command is destructive, causing every call and link using the<br />

port to be torn down.<br />

2000 ABORT Did not receive test response within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 5 times. If this problem<br />

persists, reset the circuit pack and rerun the test.<br />

2. If the problem persists, replace the circuit pack.<br />

2012 ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL The VAL or C-LAN circuit pack detected a test failure.<br />

1. Retry the command at 1-minute intervals up to 5 times. If the problem<br />

persists, reset the circuit pack and rerun the test.<br />

2. If the problem persists, replace the circuit pack.<br />

PASS Port circuitry is functioning properly.<br />