Communication Manager Maintenance Object Repair Procedures<br />

RING-GEN (Analog Ring Generator)<br />

MO Name in Log Alarm<br />

Level<br />

Initial Command to Run Full Name of MO<br />

RING-GEN MAJ test environment location Analog Ring Generator<br />

Analog phones must be provided with a voltage that allows them to ring. The Analog Ring<br />

Generator provides the ringing voltage for every analog phone associated with a given cabinet.<br />

In a multicarrier cabinet, the ring generator resides in the power distribution unit. It is protected<br />

by a fuse located next to the main circuit breaker on the front of the unit. In single-carrier<br />

cabinets, the ring generator is part of the WP-91153 power supply.<br />

Failure of the ring generator results in loss of ringing on analog phones. Ringing on digital and<br />

hybrid phones is not affected.<br />

The ringing voltage is monitored by the Tone-Clock circuit pack. In a port network with<br />

duplicated Tone-Clocks, the active Tone-Clock performs this function. In a PN made up of<br />

single-carrier cabinets, the Tone-Clock monitors the ringing voltage of only the carrier where it<br />

resides.<br />

The TN2036 Voltage Range circuit pack provides easy access for testing the various voltages<br />

on the backplane pins.<br />

Error log entries and recommended actions<br />

Table 319: RING-GEN Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test environment location<br />

1 Ring Generator<br />

Query (#118)<br />

MAJ ON test environment location r 3<br />

Note:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its procedures.<br />

1172 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s