Communication Manager Maintenance Object Repair Procedures<br />

Table 569: VC DSP Port Local TDM Loopback Test (#1104) 3 of 3<br />

Error<br />

Code<br />

0 - 3<br />

4 - 7<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The TDM Looparound test failed.<br />

The Conference Circuit test failed.<br />

1. Replace circuit pack.<br />

PASS The VC DSP Port Local TDM Looparound test passed.<br />

VC DSP Port DSP Looparound Test (#1105)<br />

This test is destructive.<br />

This test verifies the connectivity of a VC-DSPPT across the TDM bus. It aborts if calls<br />

associated with the port are in progress. Failure of this test indicates an on-board fault<br />

associated with the port hardware on the circuit pack.<br />

This test runs on VC-DSPPT (Voice Conditioner DSP Port).<br />