Error log entries and recommended actions<br />

Table 352: TBRI-TRK Error Log Entries<br />

Error Type Aux Data Associated Test Alarm<br />

Level<br />

TBRI-TRK (ISDN Trunk-Side BRI Channel)<br />

Notes:<br />

a. Error Type 0: run the Short Test Sequence first. If all tests pass, run the Long Test<br />

Sequence. Refer to the appropriate test description and follow the recommended<br />

procedures.<br />

b. Error Type 513: the far-end has reported that this channel is not administered. The trunks<br />

are placed in the out-of-service state.<br />

c. Error Type 1793: the signaling link is down:<br />

● Aux Data 8 indicates the Signaling Link is down.<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test port location<br />

513 (b) Service State Audit<br />

(#256)<br />

WRN OFF<br />

1793 (c) 8, 9 WRN OFF<br />

3073 (d) Service State Audit<br />

(#256)<br />

3585 (e)<br />

3841 (f) WRN OFF<br />

● Aux Data 9 indicates the Port is out of service.<br />

d. Error Type 3073: the Service State Audit failed. The test will be run every 15 minutes until it<br />

passes.<br />

e. Error Type 3585: unexpected Restart message. This error is logged only. No action is<br />

necessary.<br />

f. Error Type 3841: B-Channel Rejection Event. This action causes the Service State Audit,<br />

the Call State Audit, and the Test Call Audit to be executed.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1309