Communication Manager Maintenance Object Repair Procedures<br />

b. Error Type 1: DS1 Interface circuit pack or media module detects a hardware error on the<br />

DS1 DID trunk. The Aux Data field indicates the following:<br />

57476 On-hook before wink<br />

57477 On-hook before ready to receive digits<br />

57485 Wink too short for valid signal<br />

Maintenance does not start any testing or generate any alarms in response to these errors.<br />

c. Error Type 15: Software audit error that does not indicate hardware malfunction. Run short<br />

test sequence, and investigate any errors.<br />

d. Error Type 18: The trunk has been taken out of service by a demand busyout. No calls can<br />

be made on this trunk.<br />

e. Error Type 130: the circuit pack or media module has been removed or has been insane for<br />

more than 11 minutes. To clear the error, reinsert or replace the circuit pack or media<br />

module.<br />

f. Error Type 257: DS1 Interface circuit pack or media module detects a hardware error on<br />

the DS1 DID trunk. The Aux Data field indicate the source of the error:<br />

57473 Rotary dial rate above 8 pulses per second<br />

57474 Rotary dial rate below 12 pulses per second<br />

g. Error Type 513: DS1 Interface circuit pack or media module detects a hardware error on<br />

the DS1 DID trunk. Aux Data 57392 indicates no external release on PBX disconnect.<br />

h. Error Type 769: DS1 Interface circuit pack or media module detects a hardware error on<br />

the DS1 DID trunk. Aux Data 57393 indicates belated external release on PBX disconnect.<br />

i. Error Type 1793: DS1 Interface circuit pack or media module is out-of-service. Look in the<br />

error log:<br />

If port is on Look in<br />

TN767 DS1 Board DS1-BD<br />

TN464 UDS1 Board UDS1-BD<br />

DS1 Interface Media Module MG-DS1<br />

j. Error Type 2305 indicates that a signaling change was detected by the PBX trunk circuit<br />

pack or media module which is inconsistent with the present state of the trunk.<br />

k. Error Type 3840: Port Audit and Update test (#36) failed due to an internal system error.<br />

Enter status trunk to verify the status of the trunk. If the trunk is out-of-service, enter<br />

release trunk to put it back to in-service. Retry the test command.<br />