Communication Manager Maintenance Object Repair Procedures<br />

ISDN-SGR (ISDN-PRI Signaling Group)<br />

MO Name<br />

in Log<br />

Alarm<br />

Level<br />

ISDN-SGR MIN<br />

WRN<br />

An ISDN-PRI Signaling Group is a collection of B-Channels for which a given ISDN-PRI<br />

Signaling Channel Port (D-channel) carries signaling information. B-Channels carry voice or<br />

data and can be assigned to DS1 ISDN trunks (ISDN-TRK) or PRI endpoint ports (PE-BCHL).<br />

Note:<br />

Note: Throughout this discussion, the term “B-Channel” refers to an ISDN-TRK or<br />

PE-BCHL, depending on the application under investigation.<br />

The following circuit packs/media modules are supported in the implementation of ISDN-PRI:<br />

. There are two types of DS1 interfaces:<br />

● 24 DS0 channels on a 1.544-Mbps link<br />

● 31 DS0 channels + 1 framing channel on a 2.048-Mbps link<br />

The following discussion describes 24-channel interface signaling groups. The 32-channel<br />

interface works the same way, except that only port number 16 is used for signaling instead of<br />

port number 24. Ports 1 through 15 and 17 through 31 are used for B-Channels. The 32 nd<br />

channel (port 0) is always used for framing.<br />

ISDN-PRI D-channel signaling can be combined with a group of B-Channels in three basic<br />

ways:<br />

● FAS (facility-associated signaling)<br />

● NFAS (non-facility-associated signaling)<br />

● Backup NFAS signaling<br />

Initial Command to Run 1<br />

Full Name of MO<br />

1. grp# is the signaling group number (1–166); the test sequence can be either short or long.<br />

Circuit Pack/<br />

Media Module<br />

test signaling-group grp# ISDN-PRI Signaling Group<br />

Channel Types Interface<br />

MM710 B- and D-Channels 24 or 32 channel<br />

TN464B B-Channels 32 channels<br />

TN464C/D/E B- and D-Channels 24 or 32 channel<br />

TN464F/GP/HP B- and D-Channels 24 or 32 channel<br />

TN767 B-Channels only 24 channels<br />

920 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s