Communication Manager Maintenance Object Repair Procedures<br />

Table 392: Tone Detection Verification Test (#42) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT The system was not able to allocate resources needed for this test,<br />

OR there was an internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1 ABORT The system could not allocate resources needed to test the tones.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1001 ABORT The system was unable to seize the port to test it.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the test. The system may<br />

be under heavy traffic conditions, or it may have time slots<br />

out-of-service due to TDM-BUS errors. A system is considered under<br />

heavy traffic when the Call Processing Occupancy is greater than<br />

50% or when the System Management and the Call Processing<br />

Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a Tone-Clock for the test connection.<br />

This may be caused by a heavy load on the system or by a faulted<br />

Tone-Clock.<br />

1. Check to see if there are any alarms against the TONE-BD or<br />

TONE-PT in the PN where the test aborted. If so, see TONE-BD<br />

(Tone-Clock Circuit Pack) and TONE-PT (Tone Generator) for<br />

recommended procedures.<br />

2. If a new Tone-Clock has been inserted, allow about 1-minute for<br />

the system to initialize the newly inserted circuit pack.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

2000 ABORT Response from the test was not received within the time allowed.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1498 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />