09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PDMODULE (Processor Data Module)<br />

PDMODULE (Processor Data Module)<br />

Error log entries and tests also apply to TDMODULE.<br />

The PDMODULE and TDMODULE MOs monitor and test Digital Line circuit pack ports that are<br />

connected to Data Communications Equipment (DCE) or Data Terminal Equipment (DTE). DCE<br />

include processor data modules (MPDM) and Data Adaptors (DA). DTE include trunk data<br />

modules (DTE). These stand-alone data modules provide interfaces between DCP ports on the<br />

Digital Line circuit packs and data equipment such as terminals, host computers, and data<br />

modems. (See the following list and figure.) Data modules are used for dial-up and permanent<br />

circuit-switched data calls.<br />

Digital Line circuit packs also connect to digital terminal data modules (DTDMs), which work in<br />

conjunction with a voice terminal. Those configurations are covered by the DIG-LINE MO.<br />

Circuit pack-level maintenance is covered by DIG-BD whose strategy is described in the<br />

XXX-BD (Common Port Circuit Pack/Media Module).<br />

Digital line circuit packs include the TN754, TN754B, TN413, TN2136. See DIG-LINE (Digital<br />

Line) for more information about the characteristics of these circuit packs.<br />

Note: Not<br />

MO Name in Log Alarm<br />

Level<br />

PDMODULE 1<br />

TDMODULE 2<br />

Initial Command to Run Full Name of MO<br />

MIN test port location long Processor Data Module<br />

WRN test port location<br />

MIN test port location long Trunk Data Module<br />

WRN test port location<br />

1. Digital Terminal Data Modules (DTDM), and Data Adaptors (DA) in linked mode are considered part of<br />

the Digital Line MO. See the DIG-LINE section for maintenance of these devices. DAs in stand-alone<br />

mode are included in PDMODULE.<br />

Some of the alarms that are logged due to PDMODULE and TDMODULE test failures may be related to<br />

circuit-pack problems reported during DIG-BD testing. See XXX-BD (Common Port Circuit Pack/Media<br />

Module).<br />

Note:<br />

all tests that run on circuit packs are applicable to media modules. These<br />

tests will abort with error code 1412. This error can be ignored.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1065

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!