Communication Manager Maintenance Object Repair Procedures<br />

DIOD-TRK (DIOD Trunk)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

DIOD-TRK MAJ 1<br />

MIN<br />

WRN<br />

Many trunk problems are caused by incorrect settings of parameters on the trunk group<br />

administration screen. Settings must be compatible with the local environment and with<br />

parameter settings on the far end. Refer to the Administrator Guide for <strong>Avaya</strong> Communication<br />

Manager, 03-300509, for information about how to administer trunks. Refer to your <strong>Avaya</strong><br />

representative for the correct settings for administrable timers and other parameters on a<br />

country-by-country basis.<br />

Direct inward and outward dial (DIOD) trunks are 2-wire analog lines to the CO which support<br />

the following services:<br />

● Both incoming and outgoing CO calls<br />

● DID trunk<br />

● DID trunk and 1-way outgoing DIOD<br />

TN429 DIOD trunk circuit packs and MM711 Analog Media Modules provide eight ports for<br />

loop-start CO trunks and serve as an interface between the 2-wire analog CO line and the<br />

4-wire TDM bus on the switch.<br />

Not all tests that run on circuit packs are applicable to media modules. These tests will abort<br />

with error code 1412. This error can be ignored.<br />

Loop Start Operation<br />

Idle State: Tip = ground, Ring = CO Battery<br />

Outgoing Call<br />

test port location DIOD Trunk<br />

1. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by set<br />

options and that at least 75 percent of the trunks in this trunk group are alarmed.<br />

1. PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop<br />

2. CO Response: DC loop current + Dial tone<br />

3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current<br />

4. CO Response: CO goes to idle state (see Note)<br />

710 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s